APC Smart-UPS Battery Backup with Network CardOutput: 2880 VA 2700W Input: 75 154 VAC @ 50 60 Hz 2 x NEMA 5 20R (Battery Backup) 6 x NEMA 5 15R (Battery Backup) 459 Joules Surge Energy Rating Automatic Voltage Regulation (AVR) Recharge Time: up to 3 Hours Line Interactive Topology Sine Waveform Includes AP9631 Network Card The Smart UPS Battery Backup with Network Card from APC features an output of 2880 VA 2700W, an input range of 75 154 VAC @ 50 60 Hz, two NEMA 5 20R battery backup outputs, six
- Output: 2880 VA / 2700W
- Input: 75-154 VAC @ 50-60 Hz
- 2 x NEMA 5-20R (Battery Backup)
- 6 x NEMA 5-15R (Battery Backup)
- 459 Joules Surge Energy Rating
- Automatic Voltage Regulation (AVR)
- Recharge Time: up to 3 Hours
- Line Interactive Topology
- Sine Waveform
- Includes AP9631 Network Card
The Smart-UPS Battery Backup with Network Card from APC features an output of 2880 VA / 2700W, an input range of 75-154 VAC @ 50-60 Hz, two NEMA 5-20R battery backup outputs, six NEMA 5-15R battery backup outputs, a surge energy rating of 459 joules, line interactive topology, and a sine waveform. Included PowerChute Network Shutdown management software helps to provide unattended, yet proper shutdowns of network operating systems, and also included is a pre-installed APC AP9631 Network Management Card and a rack mounting rail kit. Support is provided by a limited 3-year repair or replace warranty that excludes the battery, as well as a limited 2-year battery warranty.
General Features
Adaptability
- Adjustable Voltage-Transfer Points
- Helps maximize the useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Adjustable Voltage Sensitivity
- Provides the ability to adapt the UPS for improved performance in specific power environments or generator applications.
Safety
- Safety-Agency Approved
- Helps ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Availability
- Automatic Restart of Loads After UPS Shutdown
- Automatically starts up the connected equipment upon the return of utility power.
- Automatic Self-Test
- Periodic battery self-test helps ensure early detection of a battery that needs to be replaced.
- Disconnected Battery Notification
- Warns when a battery is not available to provide backup power.
- Boost and Trim Automatic Voltage Regulation (AVR)
- Gives higher application availability by correcting low and high voltage conditions without using the battery.
- Intelligent Battery Management
- Maximizes battery performance, life, and reliability through intelligent, precision charging.
- Temperature-Compensated Battery Charging
- Helps prolong battery life by regulating the charge voltage according to battery temperature.
- Power Conditioning
- Helps protects connected loads from surges, spikes, lightning, and other power disturbances.
Manageability
- Network Manageable
- Provides remote power management of the UPS over the network.
- Audible Alarms
- Actively lets you know if the unit is on battery, if the battery is low, or if there is an overload condition.
- Disconnected Battery Notification
- Warns when a battery is not available to provide backup power.
- LED Status Indicators
- Understand unit and power status with visual indicators.
- Serial Connectivity
- Provides management of the UPS via a serial port.
- USB Connectivity
- Provides management of the UPS via a USB port.
Serviceability
- Resettable Circuit Breakers
- Helps enable a quick recovery from overload events.
- Predictive Failure Notification
- Provides early-warning fault analysis ensuring proactive component replacement.
- Hot-Swappable Batteries
- Helps ensures clean, uninterrupted power to protected equipment while batteries are being replaced.
- Battery Failure Notification
- Helps provides early-warning fault analysis on batteries, enabling preventive maintenance.
- User-Replaceable Batteries
- Increases availability by allowing a trained user to perform upgrades and replacements of the batteries, thereby reducing the Mean Time to Repair (MTTR).
Product Distribution
- Countries
- Colombia, Costa Rica, Dominican Republic, Ecuador, Guatemala, Honduras, Mexico, Nicaragua, Panama, Puerto Rico, El Salvador, and United States
- UPS Network Management Card 2 with Environmental Monitoring
- Rack Mounting Rail Kit
- PowerChute Software
- Limited Lifetime $150,000 Equipment Protection Policy
- Limited 2-Year Warranty (Battery Only)
- Limited 3-Year Repair or Replace Warranty (UPS Only)
APC 3000VA specs
| Output | |
|---|---|
| Output Power Capacity | 2700 W / 2880 VA |
| Max Configurable Power | 2700 W / 2880 VA |
| Nominal Output Voltage | 120 V |
| Output Voltage Distortion | Less than 5% |
| Output Frequency (Sync to Mains) | 50/60 Hz ±3 Hz |
| Topology | Line Interactive |
| Waveform Type | Sine wave |
| Output Connections | 2 x NEMA 5-20R (Battery Backup) 6 x NEMA 5-15R (Battery Backup) |
| Transfer Time | Typical: 4 ms Maximum 8 ms |
| Input | |
|---|---|
| Nominal Input Voltage | 120 V |
| Input Frequency | 50/60 Hz ±3 Hz (auto sensing) |
| Cord Length | 8.0' / 2.4 m |
| Input Voltage Range for Main Operations | 82 to 144 V |
| Input Voltage Adjustable Range for Mains Operation | 75 to 154 V |
| Number of Power Cords | 1 |
| Batteries & Runtime | |
|---|---|
| Battery Type | Maintenance-free sealed/leakproof lead-acid battery with suspended electrolytes |
| Typical Recharge Time | 3 hours |
| Expected Battery Life | 3 to 5 years |
| RBC Quantity | 1 |
| Communications & Management | |
|---|---|
| Interface Ports | RJ45, Serial, SmartSlot, and USB |
| Pre-Installed SmartSlot Cards | AP9631 |
| Control Panel | LED Status Display with Online On Battery Replace Battery and Overload Indicators Multi-Function LCD Status and Control Console |
| Audible Alarm | Alarm when on battery Low battery alarm Overload continuous tone alarm |
| Surge Protection and Filtering | |
|---|---|
| Surge Energy Rating | 459 joules |
| Environmental | |
|---|---|
| Temperature | Operating: 32 to 104°F / 0 to 40°C Storage: 5 to 113°F / -15 to 45°C |
| Relative Humidity | 0 to 95% |
| Elevation | Operating: 0 to 10,000' / 0 to 3,480 m Storage: 0 to 50,000' / 0 to 15,240 m |
| Audible Noise | 55 dBA at 3.3' / 1.0 m from surface of unit |
| Online Thermal Dissipation | 348 BTU/hr |
| Conformance | |
|---|---|
| Approvals | CSA, ENERGY STAR (USA), FCC Part 15 Class A, UL 1778 |
| Sustainable Offer Status | |
|---|---|
| RoHS | Compliant |
| REACH | Contains no SVHCs |
| Battery Directive | Compliant |
| Physical | |
|---|---|
| Color | Black |
| Rack Height | 2 RU |
| Dimensions | 3.39 x 18.90 x 26.89" / 8.61 x 48.01 x 68.30 cm |
| Weight | 97.62 lb / 44.28 kg |
| Packaging Info | |
|---|---|
| Package Weight | 116.0 lb |
| Box Dimensions (LxWxH) | 39.0 x 24.0 x 10.0" |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy