SKU: 10966503671

Rat FⅡ ELISA Kit

Sale price$165.71 Regular price$184.12
Save 10%

Pay in installments of $46.03 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 12 - Aug 17

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Rat FⅡ ELISA KitProduct Specification Usage Required experimental equipment: 1. Microplate reader (450nm) 2. High precision pipette and pipette tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37C constant temperature incubator 4. Distilled or deionized water Sample processing and requirements: Serum: Collect the whole blood sample in the serum separator tube at room temperature for 2 hours or at 4C overnight. Then centrifuge at 1000g for 20 minutes and remove the

Product Specification

Usage Required experimental equipment:
1. Microplate reader (450nm)
2. High-precision pipette and pipette tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL
3. 37°C constant temperature incubator
4. Distilled or deionized water

Sample processing and requirements:
Serum: Collect the whole blood sample in the serum separator tube at room temperature for 2 hours or at 4°C overnight.
Then centrifuge at 1000×g for 20 minutes and remove the supernatant.
Alternatively, store the supernatant at -20°C or -80°C, but avoid repeated freezing and thawing.

Preparation before testing:
1. Please remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature.
2. Prepare a gradient standard working solution: Add 1 mL of universal diluent to the lyophilized standard.
Let stand for 15 minutes to completely dissolve, then gently mix (concentration 250 ng/mL).
Then dilute to the following concentrations: 250 ng/mL, 125 ng/mL, 62.5 ng/mL, 31.25 ng/mL, 15.625 ng/mL, 7.8125 ng/mL, 3.90625 ng/mL, and 0 ng/mL.
Serial dilution method: Take seven EP tubes and add 500 μL of universal diluent to each tube.
Pipette 500 μL of the 250 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 125 ng/mL standard working solution.
Repeat this procedure for subsequent tubes.
The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube.
See the figure below for details.
3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use.
Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent).
Prepare and use immediately.
4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute.
Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent).
Prepare immediately.
5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal.
Allow to stand at room temperature until the crystals have completely dissolved before preparing).

Procedure:
1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes.
Seal the remaining strips in a ziplock bag and return to 4°C.
2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells.
Add 100 μL of universal diluent to the blank wells.
Cover with a film and incubate at 37°C for 60 minutes.
(Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate.
This will reduce the impact of matrix effects on the test results.
The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration.
It is recommended to run replicates for all test samples and standards.)
3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing.
Add 100 μL of Biotinylated Antibody Working Solution directly to each well.
Cover with a film and incubate at 37°C for 60 minutes.
4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well.
Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper.
Repeat this process three times (a plate washer can also be used).
5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well.
Cover with a film and incubate at 37°C for 30 minutes.
6. Washing: Discard the liquid and wash the plate five times as in step 4.
7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes.
8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well.
Immediately measure the OD value of each well at a wavelength of 450 nm.

Calculating experimental results:
1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor.
Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis.
2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest.
Multiply the sample concentration by the corresponding dilution factor.

Theory This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a Coagulation Factor II (FII) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the amount of Coagulation Factor II (FII) in the sample. The absorbance (OD value) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Rat
Synonym Rat Coagulation Factor II ELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T match set remark
Pre-coating 96 Well plate 8 Hole ×12 Strip without
Standard 2 branch
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4 Zhang
without
Instructions
1 Share
without
Background Coagulation factor II (FII, fibrinogenase, thrombin, coagulant, thrombin-C, activated blood coagulation factor II, factor IIa, type E thrombin, β-thrombin, γ-thrombin) is a serine protease encoded by the F2 gene. During coagulation, factor II is cleaved by proteins to form thrombin, which in turn acts as a serine protease, converting soluble fibrinogen into insoluble fibrin strands and catalyzing numerous other coagulation-related reactions. FII is generated by the cleavage of thrombin at two sites by activated factor X (Xa).
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 3.90-250ng/mL
Applications serum
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 10966503671

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.0 ★★★★★
Based on 28 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
S
Verified Purchase
Scott Bloomquist
Louisville, US
★★★★★ 4
Solders nice, extremely flexible maybe too flexible
Size: silicone wire red 20ft and black 20ft, Color: Red and Black
The wire solders very nicely. It's very flexible, perhaps a little too flexible. I used this wire in a couple speaker building projects. I like to put the wire in a drill and twist the wires together, it's a nice look and helps with wire management. The too flexible part makes it so the wire doesn't stay tightly twisted. To remedy that I use heat shrink at either end to at least keep the wires somewhat together.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 12, 2021
W
Verified Purchase
William M.
Dallas, US
★★★★★ 5
Quality heat resistant wire.
Size: silicone wire red 25ft and black 25ft, Color: Red and Black
Quality, heat resistant silicone wire for my heating coil wine bottle cutting project. I didn’t need very much, but provided me the best price and option. No regrets.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 16, 2025
B
Verified Purchase
Bruce
Alexandria, US
★★★★★ 5
Best for 12S high current battery wires
Size: silicone wire red 25ft and black 25ft, Color: Red and Black
High quality flexible silicone wire. Perfect for high current large motor & battery wires.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 23, 2026
M
Verified Purchase
MakerTool
Draper, US
★★★★★ 5
Loong jumper test cables.
Size: silicone wire red 25ft and black 25ft, Color: Red and Black
Over-kill makes nice tools. This is good tinned fine stranded wire with quality silicone insulation. Five-star stuff, without buying some expensive large quantity minimum from a high-end wire manufacturer.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 6, 2025
J
Verified Purchase
Jim Coughlin
Draper, US
★★★★★ 5
Good deal
Good replacement carburetor
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 22, 2026

recommand products