SKU: 1252683313

Legrand Rack PDU, Network Metered, ZeroU, 16A, 120V, (24) 5-20R, L5-20P Cord

Sale price$415.75 Regular price$461.94
Save 10%

Pay in installments of $115.48 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 13 - Aug 18

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Legrand Rack PDU, Network Metered, ZeroU, 16A, 120V, (24) 5-20R, L5-20P CordThe Legrand Rack PDU Network Metered ZeroU is a compact, high performance power distribution solution engineered for demanding data centers, server rooms, and IT closets. Designed to deliver real time power metering and effortless remote monitoring, this ZeroU PDU fits neatly behind equipment while providing full visibility into electrical load, voltage, and energy consumption. With a bright color LCD on the unit and seamless compatibility with

The Legrand Rack PDU Network Metered ZeroU is a compact, high-performance power distribution solution engineered for demanding data centers, server rooms, and IT closets. Designed to deliver real-time power metering and effortless remote monitoring, this ZeroU PDU fits neatly behind equipment while providing full visibility into electrical load, voltage, and energy consumption. With a bright color LCD on the unit and seamless compatibility with tablets and smartphones, administrators can stay ahead of capacity constraints and optimize energy use without sacrificing rack density or service uptime.

  • Real-time power metering at the line level provides accurate visibility into load, voltage, and energy consumption, enabling proactive capacity planning and energy optimization across critical IT infrastructure.
  • Network-enabled monitoring delivers remote access to usage data, configurable alerts, and user-defined conditions, helping operations teams detect anomalies and respond before issues impact performance.
  • (24) 5-20R outlets paired with an L5-20P inlet support comprehensive 120V provisioning for dense server, storage, and networking gear on standard 20A branch circuits.
  • ZeroU footprint maximizes rack space efficiency by mounting behind equipment, preserving front-panel clearance and enabling higher density deployments without sacrificing accessibility.
  • Color LCD display on the PDU surface provides local visibility of key metrics, while integration with mobile devices and management dashboards ensures convenient remote monitoring and data logging for ongoing efficiency initiatives.

Technical Details of Legrand Rack PDU

  • Form factor: Network Metered PDU with ZeroU mounting
  • Voltage: 120 VAC
  • Current rating: 16 A
  • Receptacles: (24) 5-20R outlets
  • Cord/inlet: L5-20P input cord
  • Metering: Real-time line-level power metering for precise usage data
  • Display: Color LCD screen on the PDU for local monitoring
  • Monitoring: Remote monitoring capabilities through network connectivity (web portal and supported management software)
  • Form factor details: ZeroU design for back-of-rack installation that preserves front-facing rack space

How to install Legrand Rack PDU

Installing the Legrand Rack PDU is designed to be straightforward for IT professionals familiar with rack infrastructure. Begin by assessing your rack layout to ensure the ZeroU PDU can be mounted in the rear of the rack without obstructing cable management or airflow. Verify that a suitable 120V, 16A power source is available on a dedicated circuit to support the total load of connected devices. Power down the equipment to be connected and prepare cable runs to minimize strain on connectors.

1) Mount the ZeroU PDU in the back of the rack, aligning it with available mounting rails. Secure the unit using the appropriate hardware to prevent movement during operation. 2) Connect the L5-20P inlet cord to the designated 120V circuit, ensuring a secure and code-compliant connection. 3) Route and organize the 24 receptacle cables to the devices you plan to power, taking care to balance load across the outlets and maintain adequate clearance for airflow. 4) Connect the PDU to your network according to the manual to enable remote monitoring. This may involve configuring network settings or associating the PDU with your existing management platform. 5) Power up the PDU and use the Color LCD screen to verify voltage, current, and power metrics. 6) Configure notification thresholds, alerts, and any data logging preferences to align with your operational requirements. 7) Validate the setup by monitoring real-time data, ensuring alerts trigger as expected under simulated load conditions, and confirming that the PDU safely discontinues power to outlets if configured for overcurrent or fault conditions. 8) Document the configuration and maintain routine checks to ensure ongoing reliability and energy efficiency.

Tips for optimal performance:

  • Distribute the load evenly across the 24 outlets to avoid creating hotspots on a single circuit.
  • Take advantage of the LCD data to identify underutilized outlets and adjust cable management to improve airflow.
  • Integrate the PDU with your data center infrastructure management (DCIM) tools to centralize power analytics and capacity planning.
  • Set proactive alerts for abnormal current spikes or voltage deviations to prevent potential equipment issues and downtime.

Frequently asked questions

  • Q: What is a network metered PDU? A: A network metered PDU provides real-time monitoring of electrical parameters (such as current, voltage, and power) and communicates data over a network so you can track usage, forecast needs, and set alerts across multiple racks and devices.
  • Q: What does ZeroU mean for a PDU? A: ZeroU indicates that the PDU occupies 0 rack units of vertical space, allowing it to mount in the rear of the rack without intruding on the front panel area, which helps maximize front-facing visibility and airflow for your equipment.
  • Q: Is 16A at 120V sufficient for my rack load? A: This depends on the total draw of connected devices. Plan for aggregate loads that stay well below the circuit’s rating and consider using two or more PDUs on separate circuits to distribute load evenly and maintain reliability.
  • Q: Can I monitor the PDU from mobile devices? A: Yes. The PDU’s network capability supports remote monitoring through compatible dashboards, web portals, and mobile devices, enabling convenient access to power metrics wherever you are.
  • Q: How do I ensure the PDU integrates with our DCIM tools? A: Use the PDU’s standard monitoring interfaces and data export options (e.g., SNMP or other supported protocols) to feed power analytics into your DCIM solution, enabling centralized visibility and reporting.
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 1252683313

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.2 ★★★★★
Based on 16 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
L
Verified Purchase
Lori Z.
Alexandria, US
★★★★★ 3
Does its job
Color: Black, Size: 4 Panel-88''
For the price the quality is decent. The only thing I do not love is the panels are attached to each other with 3 plastic clips. Only 1 side of the panel is actually attached to wheels. The other side kind of sits on the bar and is held in place with those clips.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 12, 2026
L
Verified Purchase
Linda Kocemba
Los Angeles, US
★★★★★ 5
Worth purchasing
Color: Black, Size: 4 Panel-88''
This is perfect definitely worth the money. It’s very easy to put together. It’s terrible material. The quality and appearance is great. It gives that privacy that you need It’s definitely worth the purchase.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 30, 2026
J
Verified Purchase
Jamie Morgan
Port Orchard, US
★★★★★ 5
Easy to assemble
Color: Black, Size: 4 Panel-88''
Fairly easy to assemble
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 16, 2026
C
Verified Purchase
Crystal
Lake Worth, US
★★★★★ 5
Great product
Color: Black, Size: 4 Panel-88''
Love this
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 23, 2026
J
Verified Purchase
Jeff
Lexington, US
★★★★★ 5
Light weight and large privacy screen
Color: Black, Color: Black
The privacy screen is light weight and of great quality. The screen can block sight and also is easy to set up. It screen is sturdy and stable. It is a cheap solution for separating paces in rooms. The privacy screen is of black color and good good in many places. It can be folded when not used and does not take much space for storage.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 19, 2025

recommand products