SKU: 22489162140

Rat COL1a1 ELISA Kit

Sale price$165.71 Regular price$184.12
Save 10%

Pay in installments of $46.03 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 9 - Aug 14

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Rat COL1a1 ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: 1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20

Product Specification

Usage Experimental equipment required for the experiment:
1. Microplate reader (450nm)
2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL
3. 37℃ constant temperature box
4. Distilled water or deionized water

Sample processing and requirements:
1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing.
2. Plasma: Collect the specimen using EDTA or heparin as an anticoagulant. Centrifuge the specimen at 1000 × g for 15 minutes at 2-8°C within 30 minutes of collection. The supernatant can be assayed or stored at -20°C or -80°C, but avoid repeated freezing and thawing.
3. Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh the tissue and mince it. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1 g of tissue sample to 9 mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000 × g for 5-10 minutes, and the supernatant can be assayed.
4. Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test.

Pre-test preparation:
1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature.
2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 20 ng/mL). Then dilute to the following concentrations: 20 ng/mL, 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, and 0 ng/mL. Serial dilution method: Take 7 EP tubes and add 500 μL of universal diluent to each tube. Pipette 500 μL of the 20 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 10 ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves directly as a blank well; there is no need to aspirate the liquid from the penultimate tube. See the figure below for details.

3. Preparation of Biotinylated Antibody Working Solution: 15 minutes before use, centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration using universal diluent (e.g., 10µL concentrate + 990µL universal diluent). Prepare immediately before use.
4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately.
5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing).

Procedure:
1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C.
2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.)
3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes.
4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used).
5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes.
6. Washing: Discard the liquid and wash the plate five times as in step 4.
7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes.
8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm.

Calculating experimental results:
1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis.
2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor.

Theory This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a capture antibody against Collagen Type I Alpha 1 (COL1a1). After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue by HRP peroxidase and to yellow by acid. The intensity of the color is positively correlated with the amount of Collagen Type I Alpha 1 (COL1a1) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Rat
Synonym Rat Collagen Type I Alpha 1 ELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T  match   set remark
Pre-coating 96 Well plate 8 Hole ×12 Strip without
Standard 2 branch
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )  
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4 Zhang
without
Instructions
1 Share
without
Background Type I collagen alpha 1, also known as alpha-1 collagen, is a protein encoded by the COL1A1 gene. COL1A1 encodes the primary component of type I collagen, a fibrous collagen found in most connective tissues, including cartilage. Collagen is a protein that strengthens and supports many tissues in the body. The COL1A1 gene produces a component of type I collagen called the tropono-α1(I) chain. This chain combines with another tropono-α1(I) chain and a tropono-α2(I) chain to form a molecule of type I procollagen. These three rope-like procollagen molecules must be processed by enzymes outside the cell. Once processed, they arrange themselves into long, thin fibrils that cross-link with each other in the space surrounding the cell. The result is the formation of very strong, mature type I collagen fibers.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 0.31-20 ng/mL
Applications Serum, plasma, tissue homogenates and other biological fluids
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 22489162140

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.0 ★★★★★
Based on 17 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
M
Verified Purchase
M. T.
West Palm Beach, US
★★★★★ 5
Excellent chair/great support.
Color: Black Full Mesh, Style: Executive
Excellent, comfortable chair! I was surprised at how easy it was to assemble---but the directions were super clear and all the pieces and parts were labeled. Once I received the chair, I was also surprised with the email follow up from Alice at Molents. All this for a reasonably priced chair.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 1, 2026
R
Verified Purchase
Rob
Carnegie, US
★★★★★ 5
Great Chair and Outstanding Customer Service
Color: Black Full Mesh, Style: Executive
I desperately needed a new office chair. I ordered this chair with the mesh seat and it spike up my sciatica. I reached out to the company and Alice took great care to address the issue. She sent me a new seat with a foam cushion and it resolved the issue immediately. The chair is incredibly comfortable with the lumbar support, adjustability and foot support. She also sent me upgraded wheels as my chair is on a thin chair mat on hard wood floors. Alice was extremely responsive with possible options and very thorough with instructions on how to replace the seat. It is a high quality chair that I anticipate will last me quite some time. I highly recommend this company and will definitely order products from them again should the need arise. Thank you, Alice!!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 10, 2026
S
Verified Purchase
Scott G
Dallas, US
★★★★★ 5
Great value and great customer experience
Color: Black Full Mesh, Style: Executive
I'm sure there are a lot of high quality chairs out there and this is one of them. For me, what sets this one apart is the customer experience from unboxing and assembly to customer care. The chair came in a surprisingly small box. To my surprise, the parts were wrapped in foam and then again in a high quality foil/foam packing material. Everything was well protected, densely packed, yet easy to unpack and locate the parts. The assembly process was straight forward as you might expect, but the attention to detail is remarkable. For example, the screws have thread lock (a dab of the blue "goo" to keep them from coming loose). Another example is the Allen wrench they give you. It isn't a cheap L-shaped wrench. It's a T-bar with a good sized handle. The parts all have slotted screw holes to give some tolerance in lining up the screws and a little bit of adjustment room. The instructions even showed how to use the box as a bench of sorts. You can tell the designers really thought about the assembly process. The chair came with a tag offering a free "upgraded foam seat protector cover" by sending them an email. Not only did they send one, the email response was from a human (I'm 99% positive) that asked how I liked the chair. I honestly responded that I like the arms to go down lower than this chair allows and said I might modify it. We exchanged a few messages about it and they ended up sending me some washers/spacers. It now fits my frame perfectly. Not only that, they offered to send me a different set of wheels that are more suitable for my flooring, which I took them up on. I didn't even ask! In summary, I am extremely happy with this chair and the company I bought it from. It is a fantastic value.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 18, 2026
C
Verified Purchase
Camryn
Cuba, US
★★★★★ 5
Great Chair! Worth the Price!
Color: Sky Blue, Size: Pack of 1
LOVE my new desk chair! I got the Sky Blue which is a really pretty blue in person. I work from home in tech, and had been getting constant headaches no matter what position I was in. I finally decided to invest in a better desk chair, and I'm SO glad I did! It's much more supportive and comfortable. I really like that I can flip the arms up or down, and the height is easy to adjust. Also, because I can flip the arms up, I can keep the chair out of the way when I'm not working by putting it right up against the desk. Very much worth the price! Assembly was simply and quick. Not even 30 minutes. Also, when I had a question about the chair, their support team was quick to respond and very helpful. Highly recommend!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 2, 2026
D
Verified Purchase
David Miller
Massapequa, US
★★★★★ 5
Great quality chair, regardless of price.
Color: Black+white, Size: Pack of 1, Color: Black+white, Size: Pack of 1
Great quality chair, regardless of the price, period. So well packaged that it took almost as long to unwrap as assemble. Assembly was easy (loved the Allen wrench with sturdy handle). I am 6'2" and the fit and height adjustments work well for my height. Comfort is personal, so I like the semi-firmness of the seat. While the chair is constructed of heavy gauge plastic the base is solid metal with enamel finish: I love the look. The arm rests line up perfectly to my computer keyboard. I expect many, many years of service.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 17, 2026

recommand products