Pay in installments of $46.03 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Aug 12 - Aug 17
For Your Every Summer RSVP, with Code: SUMMER15
Description
Human DMT1 ELISA KitProduct Specification Usage Required experimental equipment: 1. Microplate reader (450nm) 2. High precision pipettes and pipette tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre chilled PBS (0. 01M, pH 7. 4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and
Product Specification
| Usage | Required experimental equipment: 1. Microplate reader (450nm) 2. High-precision pipettes and pipette tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37°C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and mince the tissue. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1g of tissue sample to 9mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000×g for 5-10 minutes, and collect the supernatant for analysis. Cell Lysis Buffer: Adherent cells should be gently washed with pre-chilled PBS, then trypsinized and harvested by centrifugation at 1000×g for 5 minutes. Suspension cells can be harvested directly by centrifugation. Collected cells should be washed three times with pre-chilled PBS and resuspended in 150-200 μL of PBS per 1×10^6 cells (it is recommended to add protease inhibitors to the PBS; if the cell count is very low, reduce the PBS volume appropriately). Disrupt the cells by repeated freezing and thawing or sonication. Centrifuge the extract at 1500×g for 10 minutes at 2-8°C, and collect the supernatant for analysis. Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test. Pre-test preparation: 1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 10 ng/mL). Then dilute to the following concentrations: 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, 0.15625 ng/mL, and 0 ng/mL. Serial dilution method: Take seven EP tubes and add 500uL of universal diluent to each. Pipette 500uL of the 10ng/mL standard working solution into the first EP tube and mix thoroughly to make a 5ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details. 3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor. |
|||||||||||||||||||||||||||||||||
| Theory | This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a capture antibody against natural resistance-associated macrophage protein 2 (DMT1). After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue by peroxidase (HRP) catalysis and to yellow by acid. The intensity of the color is positively correlated with the amount of natural resistance-associated macrophage protein 2 (DMT1) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration. | |||||||||||||||||||||||||||||||||
| Source | Human | |||||||||||||||||||||||||||||||||
| Synonym | Human Natural resistance-associated macrophage protein 2 ELISA Kit | |||||||||||||||||||||||||||||||||
| Detection Type | Double antibody sandwich method | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | Divalent metal transporter 1 (DMT1), also known as divalent cation transporter 1 (DCT1) or natural resistance-associated macrophage protein 2 (NRAMP 2), is a protein encoded by the SLC11A2 (solute carrier family 11, member 2) gene. It represents a large family of orthologous metal ion transporters. As its name suggests, it binds a variety of divalent metals, including cadmium, copper, and zinc. | |||||||||||||||||||||||||||||||||
| General Notes | 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit. 8. Do not use expired products, and do not mix components with different product numbers and batches. 9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened kit is stored at 4°C, the shelf life is 6 months. | |||||||||||||||||||||||||||||||||
| Test Range | 0.156-10 ng/mL | |||||||||||||||||||||||||||||||||
| Applications | Tissue homogenates, cell lysates, and other biological fluids |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.5 ★★★★★
Based on 20 reviews
Sort
Product Reviews
★★★★★ 3
Not the best.
Size: 16.5 Inch, Color: Rustic Brown, Size: 16.5 Inch, Color: Rustic Brown
The wood style is burned wood without any sealant. I would have given a better rating but some of the shelving was bowed which makes it not look as appealing. Pretty easy to install. Definitely will need your impact. I can’t imagine trying to do that with a hand held screwdriver.
With the wood being bent the quality isn’t what I would want it to be. It can hold a decent amount of weight. But certainly not made for books. Even with wall anchors.
It gives you the option to hang it as shown in its picture or the other way where the supports are flipped.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 25, 2026
★★★★★ 5
Solid Floating Shelves 🛠️🏠
Color: Black, Number Of Shelves: 4, Size: 15.7in
I have installed four sets of the black floating shelves in my office. They are made of high quality materials, featuring a sophisticated black woodgrain finish with a natural texture. Supposedly, each unit can handle up to 22 pounds, though I would not recommend testing that limit with your vintage bowling ball collection if you value your flooring. They are awesome.
The value is good for a set of two. Each shelf measures 22x7x1 (56x17x3 cm) inches, providing a decent amount of storage for books or decor. The installation was straightforward since the hardware for multiple wall types was included. They work well in the kitchen for spices or in the bedroom for personal belongings.
One tip for a secure fit: use a level during installation and make sure the bracket is flush against the wall before sliding the shelf on, or your photos might look like they are sliding off a mountain 📐
These shelves offer a clean, modern look and stay stable once mounted correctly. They are a practical choice for adding functional display space to any room 🖼️
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 4, 2026
★★★★★ 5
Good looking shelves and easy install - skip the included drywall anchors
Color: Black, Number Of Shelves: 2, Size: 22in
I installed these shelves in a bedroom to get things off my dresser and some decor. Once mounted they look really nice. The black finish looks clean and modern and they blend in well with the room.
Installation was pretty straightforward. The metal bracket mounts to the wall first and then the shelf slides over the bracket. As long as you take your time lining things up it’s a simple project.
One thing I strongly recommend is not using the white plastic self-drilling drywall anchors that come with the kit. I’ve used that style before on other projects and they tend to strip out easily and leave larger holes in drywall. I used better anchors instead and the shelves mounted much more securely.
The rest of the hardware worked fine and once installed the shelves feel solid and hold items well.
Pros
- Clean modern look
- Easy installation
- Feels solid once mounted
- Good size for books or decor
Cons
- The small level included isn’t very accurate — use your own level
- One of the metal brackets was slightly bent out of the box but straightened out easily
Helpful tip:
Use your own level and better drywall anchors if you have them. It makes installation easier and the shelves will mount much more securely.
Final thoughts:
For the price these are nice looking floating shelves that install easily and work well for light storage and decor.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 13, 2026
★★★★★ 5
Cheap, and effective!
Color: Black, Number Of Shelves: 4, Size: 15.7in
Looks good, works great, low cost. I'll be purchasing more in the future.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 12, 2026
★★★★★ 4
Cute for coffee bar!
Color: Black, Number Of Shelves: 4, Size: 15.7in
Great for above my coffee bar. Easy to mount and align. Seems stable!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 14, 2026