SKU: 55734740346

Panduit P24D31M Vertical Intelligent Power Distribution Unit

Sale price$828.26 Regular price$920.29
Save 10%

Pay in installments of $230.07 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 16 - Aug 21

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Panduit P24D31M Vertical Intelligent Power Distribution UnitThe Panduit SmartZone G5 iPDU, manifested in the P24D31M vertical form factor, is more than a power strip. It is a comprehensive power distribution and environmental intelligence solution engineered for modern data centers, colocation facilities, and enterprise IT rooms. Designed to sit at the cabinet or rack level, this iPDU continuously monitors electrical power, detects overloads, and tracks critical environmental conditions that can affect uptime

The Panduit SmartZone G5 iPDU, manifested in the P24D31M vertical form factor, is more than a power strip. It is a comprehensive power distribution and environmental intelligence solution engineered for modern data centers, colocation facilities, and enterprise IT rooms. Designed to sit at the cabinet or rack level, this iPDU continuously monitors electrical power, detects overloads, and tracks critical environmental conditions that can affect uptime and performance. By combining precise energy metering with proactive monitoring, the P24D31M helps IT teams optimize energy use, reduce risk of outages, and gain actionable visibility into the health of the data center’s most vital assets.

  • Comprehensive power distribution with real-time energy measurement: The P24D31M integrates a robust power distribution framework with advanced energy metering, delivering real-time data on voltage, current, power, and energy consumption. Its per-outlet monitoring capabilities let you see which devices draw the most power, enabling smarter capacity planning, better load balancing, and targeted conservation strategies at the rack level.
  • Intelligent overload protection and proactive alerts: Built to prevent outages, the iPDU continuously scans electrical circuits for overloads and abnormal conditions. configurable alarms and thresholds alert administrators the moment a risk is detected, helping you take immediate action before IT services are impacted. This proactive approach reduces mean time to recovery and extends equipment life by preventing stress on power rails.
  • Advanced environmental sensing for rack-level health: Beyond power, the P24D31M brings environmental intelligence to the cabinet with sensors that monitor temperature, humidity, and airflow. By correlating electrical load with environmental data, you can identify hotspots, optimize cooling strategies, and ensure lamps, servers, and storage devices operate within safe conditions for longer lifespans.
  • Remote management, analytics, and seamless integration: The iPDU includes secure remote management via web UI, SNMP, and other standard protocols. Rich dashboards, automated reporting, and event logs provide deep analytics for capacity planning and incident investigation. Integrations with DCIM tools let you centralize monitoring across your data center floor, improving situational awareness and operational efficiency.
  • Flexible installation and durable design for data center reliability: The vertical form factor is optimized for dense rack environments, delivering a compact footprint without sacrificing access to outlets or sensors. Its rugged construction supports mission-critical deployments, and its modular approach accommodates future scalability, ensuring long-term value as IT deployments evolve.

Technical Details of Panduit P24D31M

  • Model: Panduit P24D31M Vertical iPDU (SmartZone G5)
  • Monitoring Capabilities: Real-time power usage, per-outlet measurements, total energy consumption, circuit overload detection
  • Environmental Sensors: Temperature, humidity, and airflow monitoring at the rack/cabinet level
  • Management & Connectivity: Web-based management interface, SNMP support, alerting and event logging
  • Physical Configuration: Vertical rack-mountable design, compatible with standard 19-inch racks

How to install Panduit P24D31M

Preparing for installation begins with a plan to place the P24D31M in a suitable rack location with adequate airflow and accessibility for cabling and maintenance. Ensure the rack area meets the recommended temperature range and that there is network connectivity for management access. Separate high-power devices from sensitive equipment to minimize electrical interference and ensure proper grounding for safety.

Step 1: Mount the iPDU in the rack. Use the supplied mounting hardware to secure the unit to a stable rack rail, ensuring there is sufficient clearance for cable management and ventilation. The vertical orientation should align with the rack’s rear rail to enable clean cable routing and easy access to outlets.

Step 2: Connect the power supply. Attach the iPDU’s input power cord to a suitable power source that meets the unit’s electrical requirements. Verify that the source is on, stable, and wired to a dedicated circuit where possible to minimize noise and voltage fluctuations that can affect measurements.

Step 3: Cable IT devices to the PDU outlets. Use appropriately rated power cables to connect servers, storage arrays, and networking gear to the PDU outlets. Keep power cables organized to prevent overheating and to support easy identification of circuits during troubleshooting.

Step 4: Establish management connectivity. Connect the iPDU’s management port to your network using a secure Ethernet connection. Configure IP address, gateway, and DNS as needed so you can access the web UI and begin collecting telemetry data.

Step 5: Configure monitoring and alerts. Log in to the web UI and set up alarm thresholds for temperature, humidity, and power load. Enable event logging, email or SNMP trap notifications, and define dashboards that reflect the data center’s unique topology and compliance requirements.

Step 6: Calibrate sensors and validate operation. If the iPDU permits calibration, perform sensor calibration according to the vendor guidelines. Confirm that outlet-level readings, total energy usage, and environmental sensors are reporting accurately. Validate that alarms trigger as configured and that data populates in dashboards and reports for ongoing analysis.

Step 7: Integrate with DCIM and ITSM workflows. If you use a Data Center Infrastructure Management (DCIM) platform or IT service management tools, map the iPDU data into these systems to enable centralized monitoring, incident correlation, and proactive capacity planning. This integration unlocks deeper insights and reduces the effort required to maintain optimal data center performance.

Step 8: Train operators and establish operational procedures. Document access credentials, maintenance windows, and escalation paths. Train staff on how to interpret energy and environmental data, respond to alerts, and perform routine checks that keep the P24D31M functioning reliably over time.

The Panduit P24D31M is designed to streamline power management and environmental visibility in demanding data center environments. By combining robust electrical distribution with real-time telemetry and intelligent alerting, this vertical iPDU helps IT teams prevent outages, optimize cooling, and maximize equipment effectiveness—ultimately contributing to lower total cost of ownership and higher service levels for end users.

Frequently asked questions

Q: What is the Panduit P24D31M used for? A: It is a vertical intelligent PDU that distributes power to rack equipment while providing real-time energy measurement, per-outlet monitoring, and environmental sensing to improve data center reliability and efficiency.

Q: What kind of alerts does the P24D31M support? A: The iPDU supports configurable thresholds and alerts for overload conditions, temperature, humidity, and other environmental metrics. Alerts can be delivered via the web UI, email, or SNMP traps depending on configuration.

Q: Can the P24D31M integrate with a DCIM platform? A: Yes. The device offers standard management interfaces (such as SNMP and a web-based interface) that enable integration with DCIM tools for centralized monitoring and analytics.

Q: How does energy data help with IT operations? A: Real-time energy data supports capacity planning, cost allocation, and efficiency initiatives. By identifying peak loads and underutilized circuits, teams can rebalance workloads, optimize cooling, and reduce energy waste in the data center.

Q: Is installation difficult for non-specialists? A: While a basic level of electrical safety and rack handling knowledge is recommended, Panduit provides configuration guidance and a user-friendly interface to simplify setup. If in doubt, consult your facilities or IT team or engage a qualified technician.

Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 55734740346

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.2 ★★★★★
Based on 5 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
H
Verified Purchase
Hugh G Koch
Natrona Heights, US
★★★★★ 5
A great socket.
Size: 27mm
Got it for a bmw oil filter housing. It does its job great.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 4, 2024
T
Verified Purchase
The Central Scrutinizer
Louisville, US
★★★★★ 5
Gets Job Done. Good Price.
Size: 36mm
I used this to take the large bolt off the triple tree clamp on my motorcycle. For this purpose it worked great. I doubt I'll need to do this often and I'm unlikely to ever own the vehicles who's oil filter it fits but glad I bought it. If you need a 36mm bolt undone and have a 3/8th drive wratchet this is an economical way to get it done.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on October 29, 2017
H
Verified Purchase
Hummus man
Lake Worth, US
★★★★★ 4
A good product for a good price.
Size: 36mm
it was the right size, what more could I ask for and no profile that's the bomb.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 18, 2018
L
Verified Purchase
lacey_girl
Pawtucket, US
★★★★★ 5
High quality
Size: 36mm
Perfect fit for my 2008 Audi TT oil filter cap. FYI, don't bother removing the plug in the cap if it is stripped. Mine was stripped by Audi mechanics and I thought it held the cap in place. It does not. I tried to loosen it with a chisel and broke the cap. An expensive, rookie mistake.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 3, 2023
A
Verified Purchase
AAdkerson
Pawtucket, US
★★★★★ 5
Socket
Size: 24 / 36mm
A must have for f250 makes changing filters easy
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 24, 2024

recommand products