SKU: 68032684919

Human TXNIP ELISA Kit

Sale price$165.71 Regular price$184.12
Save 10%

Pay in installments of $46.03 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 16 - Aug 21

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Human TXNIP ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: 1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20

Product Specification

Usage Experimental equipment required for the experiment:
1. Microplate reader (450nm)
2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL
3. 37℃ constant temperature box
4. Distilled water or deionized water

Sample processing and requirements:
1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing.
2. Plasma: Collect the specimen using EDTA or heparin as an anticoagulant. Centrifuge the specimen at 1000 × g for 15 minutes at 2-8°C within 30 minutes of collection. The supernatant can be assayed or stored at -20°C or -80°C, but avoid repeated freezing and thawing.
3. Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh the tissue and mince it. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1 g of tissue sample to 9 mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000 × g for 5-10 minutes, and the supernatant can be assayed.
4. Cell Lysis Buffer: Gently wash adherent cells with ice-cold PBS, then trypsinize and collect cells by centrifugation at 1000×g for 5 minutes. Suspension cells can be collected directly by centrifugation. Wash collected cells three times with ice-cold PBS and resuspend in 150-200 μL of PBS per 1×10^6 cells (it is recommended to add protease inhibitors to the PBS; if the cell count is very low, reduce the PBS volume appropriately). Disrupt the cells by repeated freeze-thaw cycles or sonication. Centrifuge the extract at 1500×g for 10 minutes at 2-8°C, and remove the supernatant for analysis.
5. Cell Culture Supernatant: Centrifuge at 1000×g for 20 minutes. Remove the supernatant for analysis or store at -20°C or -80°C, avoiding repeated freeze-thaw cycles.
6. Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test.

Pre-test preparation:
1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature.
2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 10 ng/mL). Then dilute to the following concentrations: 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, 0.15625 ng/mL, and 0 ng/mL. Serial dilution method: Take seven EP tubes and add 500uL of universal diluent to each. Pipette 500uL of the 10ng/mL standard working solution into the first EP tube and mix thoroughly to make a 5ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details.
3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately.
4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately.
5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing).

Procedure:
1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C.
2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.)
3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes.
4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used).
5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes.
6. Washing: Discard the liquid and wash the plate five times as in step 4.
7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes.
8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm.

Calculating experimental results:
1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis.
2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor.

Theory This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a thioredoxin-interacting protein (TXNIP) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the amount of thioredoxin-interacting protein (TXNIP) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Human
Synonym Human Thioredoxin-interacting protein ELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T  match   set remark
Pre-coating 96 Well plate 8 Hole ×12 Strip without
Standard 2 branch
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )  
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4 Zhang
without
Instructions
1 Share
without
Background Thioredoxin-interacting protein (TXNIP) is a protein encoded by the TXNIP gene. It belongs to a family of thioredoxin (TRX)-binding proteins and mediates oxidative stress, inhibits cell proliferation, and induces apoptosis by inhibiting the function of the thioredoxin system. It is a core molecule in the insulin-induced inflammatory process, which leads to the death of insulin-producing cells in the pancreas. It has been shown to interact with thioredoxin and ZBTB32.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 0.156-10 ng/mL
Applications Serum, plasma, tissue homogenate, cell lysate, cell culture supernatant and other biological fluids
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 68032684919

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.3 ★★★★★
Based on 14 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
C
Verified Purchase
Christopher
Omaha, US
★★★★★ 4
Solid performance, average low-light quality
Size: 1 Pack, Style: 1080P/30 fps, 720p/30fps, Pattern: Webcam
The Logitech C920x is a reliable webcam that delivers solid 1080p video quality for everyday use. Image clarity is good, colors look natural, and autofocus works well for video calls, streaming, and basic recording. Setup is straightforward and it works immediately with most conferencing and streaming software. The built-in microphones are usable for casual calls and pick up voices clearly in a quiet room. One downside is that performance in low-light conditions isn’t great. Without good lighting, the image can become grainy and lose detail, and the autofocus may hunt a bit. The microphones are also average at best and won’t replace a dedicated mic. Overall, it’s a dependable webcam that does what it’s known for, but proper lighting makes a big difference.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 17, 2026
M
Verified Purchase
Monika Patterson
Massapequa, US
★★★★★ 5
Surprisingly good quality for the price
Size: 1 Pack, Style: 1080P/30 fps, 720p/30fps, Pattern: Webcam, Size: 1 Pack, Style: 1080P/30 fps, 720p/30fps, Pattern: Webcam
I honestly wasn’t expecting much from this little webcam, but I’ve been pleasantly surprised by how good it looks once plugged in. The video quality is clear enough for Zoom calls, online classes, or everyday use, and setup was very simple. My laptop camera quality is terrible, so this was a noticeable upgrade right away. I also like that it clips securely onto the top of the screen and doesn’t feel bulky. The picture looked smoother and brighter than I expected for a budget-friendly webcam. I love how it folds up and is very adjustable. Overall, this ended up being a great little camera for the price and works well for basic streaming, meetings, and video chats.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 18, 2026
K
Verified Purchase
Kate Jarvis
Lexington, US
★★★★★ 5
Logitech doesn’t disappoint!
Size: 1 Pack, Style: 1080P/30 fps, 720p/30fps, Pattern: Webcam
This camera does not disappoint! I’ve been a Logitech loyalist for years so I had no hesitation ordering the C920. This model is small and seamless for setup w/an easy to use control dashboard. Lighting adjustments are stellar and the auto functionality helps any novice produce great media. The small size allows for superior grip anywhere you’re wanting to get that perfect angle. 5/5 great product!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 6, 2026
D
Verified Purchase
Devin Nikkole Blankenship
Natrona Heights, US
★★★★★ 5
Great Picture Quality, Easy Setup, and Works Well in Low Light
Size: 1 Pack, Style: 1080P/30 fps, 720p/30fps, Pattern: Webcam
This webcam was very easy to set up and worked right away without any issues. It is simple to use and does not require anything complicated to get started. The picture quality is clear and sharp, and it looks good for video calls and recording. It also handles low light surprisingly well and does not get too grainy. It is versatile and works well for different uses like meetings, streaming, or general use. The fit on top of the monitor is secure and stays in place without slipping or needing adjustment. Overall, it is easy to use, has great picture quality, and performs well in different lighting conditions.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 27, 2026
R
Verified Purchase
RMC
Lake Worth, US
★★★★★ 5
Great camera, lots of features, easy to setup and use
Size: 1 Pack, Style: 1080P/30 fps, 720p/30fps, Pattern: Webcam
Went from an eMeet camera to this, and I regret ever having spent money on anything other than this one. Camera looks great even with inconsistent lighting. Software features (ability to zoom in, move center of image, etc.) are extremely helpful.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 23, 2026

recommand products