Pay in installments of $75.80 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Aug 9 - Aug 14
For Your Every Summer RSVP, with Code: SUMMER15
Description
Mouse ERa ELISA KitProduct Specification Usage Required experimental equipment: 1. Microplate reader (450nm) 2. High precision pipettes and pipette tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre chilled PBS (0. 01M, pH 7. 4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and
Product Specification
| Usage | Required experimental equipment: 1. Microplate reader (450nm) 2. High-precision pipettes and pipette tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37°C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and mince the tissue. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1g of tissue sample to 9mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000×g for 5-10 minutes, and collect the supernatant for analysis. Cell Lysis Buffer: Adherent cells should be gently washed with pre-chilled PBS, then trypsinized and harvested by centrifugation at 1000×g for 5 minutes. Suspension cells can be harvested directly by centrifugation. Collected cells should be washed three times with pre-chilled PBS and resuspended in 150-200 μL of PBS per 1×10^6 cells (it is recommended to add protease inhibitors to the PBS; if the cell count is very low, reduce the PBS volume appropriately). Disrupt the cells by repeated freezing and thawing or sonication. Centrifuge the extract at 1500×g for 10 minutes at 2-8°C, and collect the supernatant for analysis. Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test. Pre-test preparation: 1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 20 ng/mL). Then dilute to the following concentrations: 20 ng/mL, 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, and 0 ng/mL. Serial dilution method: Take 7 EP tubes and add 500 μL of universal diluent to each tube. Pipette 500 μL of the 20 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 10 ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves directly as a blank well; there is no need to aspirate the liquid from the penultimate tube. See the figure below for details. 3. Preparation of Biotinylated Antibody Working Solution: 15 minutes before use, centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration using universal diluent (e.g., 10µL concentrate + 990µL universal diluent). Prepare immediately before use. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor. |
|||||||||||||||||||||||||||||||||
| Theory | This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with Estrogen Receptor Alpha (ERa) capture antibodies. After incubation and washing, the sample is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the amount of Estrogen Receptor Alpha (ERa) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration. | |||||||||||||||||||||||||||||||||
| Source | Mouse | |||||||||||||||||||||||||||||||||
| Synonym | Mouse Estrogen Receptor Alpha ELISA Kit | |||||||||||||||||||||||||||||||||
| Detection Type | Double antibody sandwich method | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | Estrogen receptor α (ESR1), also known as NR3A1 (nuclear receptor subfamily 3, group A, member 1), is one of the two major types of estrogen receptors. It is a nuclear receptor activated by the sex hormone estrogen. Encoded by the ESR1 (EStrogen Receptor 1) gene, it is a ligand-activated transcription factor composed of several domains important for hormone binding, DNA binding, and transcriptional activation. | |||||||||||||||||||||||||||||||||
| General Notes | 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit. 8. Do not use expired products, and do not mix components with different product numbers and batches. 9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened kit is stored at 4°C, the shelf life is 6 months. | |||||||||||||||||||||||||||||||||
| Test Range | 0.31-20 ng/mL | |||||||||||||||||||||||||||||||||
| Applications | Tissue homogenates, cell lysates, and other biological fluids |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.9 ★★★★★
Based on 5 reviews
Sort
Product Reviews
★★★★★ 1
Cheap garbage
Flimsy and not real pipe. Getting real tired of this cheap low quality trash coming from Amazon
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on October 19, 2024
★★★★★ 2
A good idea that didn't work out
The pieces are not labeled at all, the paint on the threads makes it difficult to get a good tight fit between the pieces, and the way the pipes are screwed together there are two opposing corners that always bow in an make it look like it's going to fall in. It's also really difficult to make level.
I really wanted to like this because it fit EXACTLY what I wanted to use it for, but I just can't trust it long term which is why I'm giving it 2 stars.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 5, 2024
★★★★★ 5
Looks great & saves space
Color: Rustic Brown and Black, Color: Rustic Brown and Black
I couldn't be happier with the look and the space it's saving me. It came very well packaged, even with corner guards on the wood shelfs. It was very easy to assemble and attach to the end of my pantry in the kitchen. That space was just going to waste. The ladder shelf fit perfect and looks great. I love the color and texture of the wood grain, it really goes well with the black metal rail. It will be a little wobbly until you get it screwed down to the wall but after that, it's good and sturdy. The instructions were easy enough to read but I still found a couple of parts I didn't use and wondered what they were for? The parts do come numbered but only on the packaging? Not on the part itself which would have been more helpful to some extent. So just keep it all together with it's packaging and you'll have no problems. Very happy with purchase.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on July 31, 2023
★★★★★ 5
Nice and sleek
Color: Rustic Brown and Black
I’m really happy with the bookshelves overall, I only wish they had taller ones available. It was very quick and easy to put together and they have held up well so far. They look great for the price and I especially like that they have a small footprint when it comes to how much room they take up.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 5, 2024
★★★★★ 5
Nice, sturdy and easy to assemble.
Color: Rustic Brown and Black, Color: Rustic Brown and Black
Worked great for our small apartment. We needed something to fit over our heater baseboard and this worked! However, we had to swap the bottoms and top side rods to fit this way, meaning instead of using the 6” rods at the bottom we put them on top and used the 12” at bottom to clear over the baseboards. Easy to assemble and matched our other larger wall shelf perfectly.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 22, 2025
recommand products
Caution & Emotions & Music Box & Ballads
60.77
Thickfreakness & Brothers (Deluxe Remastered Anniversary Edition) & Chulahoma
105.44
Duran Duran - Future Past & Future Past (Transparent Red LP Vinyl) (I) & All You Need Is Now (Magenta Vinyl/2LP) (I) & Astronaut (Milky Clear Vinyl/2LP) (I) & Red Carpet Massacre (Translucent Ruby Vinyl/2LP) (I) & Pop Trash (2LP) & Rio (2009
175.93
Greatest Hits 2 (180G/Dl Card) & Innuendo (2LP) & News Of The World & Day At The Races & Sheer Heart Attack (Half-Speed LP Vinyl) & Night At The Opera & Greatest Hits 1 (180G)
123.70
Purple Rain & Musicology (Digipak) & For You & 1999 (X) & Sign O’ The Times
77.87