Pay in installments of $46.03 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Aug 13 - Aug 18
For Your Every Summer RSVP, with Code: SUMMER15
Description
Human CHOP ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20
Product Specification
| Usage |
Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37℃ constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing. Plasma: Collect the specimen using EDTA or heparin as an anticoagulant. Centrifuge the specimen at 1000 × g for 15 minutes at 2-8°C within 30 minutes of collection. The supernatant can be assayed or stored at -20°C or -80°C, but avoid repeated freezing and thawing. Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh the tissue and mince it. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1 g of tissue sample to 9 mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000 × g for 5-10 minutes, and the supernatant can be assayed. Cell Lysis Buffer: Gently wash adherent cells with ice-cold PBS, then trypsinize and collect cells by centrifugation at 1000×g for 5 minutes. Suspension cells can be collected directly by centrifugation. Wash collected cells three times with ice-cold PBS and resuspend in 150-200 μL of PBS per 1×10^6 cells (it is recommended to add protease inhibitors to the PBS; if the cell count is very low, reduce the PBS volume appropriately). Disrupt the cells by repeated freeze-thaw cycles or sonication. Centrifuge the extract at 1500×g for 10 minutes at 2-8°C, and remove the supernatant for analysis. Cell Culture Supernatant: Centrifuge at 1000×g for 20 minutes. Remove the supernatant for analysis or store at -20°C or -80°C, avoiding repeated freeze-thaw cycles. Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test. Pre-test preparation: 1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 10 ng/mL). Then dilute to the following concentrations: 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, 0.15625 ng/mL, and 0 ng/mL. Serial dilution method: Take seven EP tubes and add 500uL of universal diluent to each. Pipette 500uL of the 10ng/mL standard working solution into the first EP tube and mix thoroughly to make a 5ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details. 3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor. |
|||||||||||||||||||||||||||||||||
| Theory | This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with an endoplasmic reticulum stress-related proteins (CHOP) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the amount of endoplasmic reticulum stress-related proteins (CHOP) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration. | |||||||||||||||||||||||||||||||||
| Source | Human | |||||||||||||||||||||||||||||||||
| Synonym | Human Endoplasmic reticulum stress-related proteins ELISA Kit | |||||||||||||||||||||||||||||||||
| Detection Type | Double antibody sandwich method | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | Endoplasmic reticulum stress-associated protein (CHOP), also known as a fusion protein, is a protein produced by linking two or more genes that originally encoded separate proteins. Translation of these genes produces one or more polypeptides that inherit the functional properties of each of the original proteins. Recombinant fusion proteins are artificially created using recombinant DNA technology for use in biological research or therapy. Some fusion proteins incorporate entire polypeptides, thus containing all the functional domains of the original proteins. However, naturally occurring fusion proteins only incorporate a portion of the coding sequence and therefore fail to retain the original function of the genes that formed them. With partial gene fusions, the shuffling of different active sites and binding domains can potentially lead to new proteins with novel functions. | |||||||||||||||||||||||||||||||||
| General Notes | 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit. 8. Do not use expired products, and do not mix components with different product numbers and batches. 9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened kit is stored at 4°C, the shelf life is 6 months. | |||||||||||||||||||||||||||||||||
| Test Range | 0.156-10 ng/mL | |||||||||||||||||||||||||||||||||
| Applications | Serum, plasma, tissue homogenate, cell lysate, cell culture supernatant and other biological fluids |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.4 ★★★★★
Based on 14 reviews
Sort
Product Reviews
★★★★★ 5
Nice office chair
Color: Beige
I recently purchased this chair for my home office setup. This chair is very comfortable and feels sturdy right out of the box. The seat cushion is thick and supportive, the back provides good support. I really like the flip-up armrests, which make it easy to slide the chair under my desk. Assembly was simple and didn't take long. Overall, it's a solid, well-built chair and a great value for the price.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 15, 2026
★★★★★ 5
Stylish, comfortable, and very practical
Color: Black, Color: Black
This chair is both cuteand funtional. The wide seat is super comfortable, especially for sitting cross-legged, and the flip-up arms are really convenient. I also like the side pockets for small items. It rolls smoothly, feels sturdy, and was easy to asssemble. Perfect for a home office or vanity setup.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 20, 2026
★★★★★ 5
Great Buy
Color: Black
Easy to assemble, very comfortable and stylish! Wheels dont roll too easily but thats an easy fix so overall very happy with this
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 28, 2026
★★★★★ 4
Seat width short (Not tall people friendly) Very nice otherwise.
Color: Beige
I like the chair a lot. It’s very sleek and modern. One problem I have with it tho is the width of the seat. I am 5’9 and not necessarily a petite woman and when I do sit cross cross I seem to hang off the front. I do like that I can sit cross cross even with the sides of the chair up but the fact that I hang off the front is a bit annoying. There are plenty of other ways to sit on it tho and being able to maneuver it to where I can sit different ways is nice. I would say that this chair isn’t exactly tall people friendly. Also pay attention to the height and width of your desk because it isn’t exactly universal to fit under a normal desk. It is also super easy to put together and instructions are clear. Also as expected the back of the seat is a bit short and personally for me I like that a lot but word of caution for others that want the back of the chair to go up their entire back. I like it shorter because I’m able to sit sideways and have one side of the chair up and the other down and using the back rest as an arm rest. I did just buy it and am slightly concerned for it to not last purely because the manual said not to use it if it squeaked of creaked and it does both of those things. But I will still be using it until it breaks or it’s life span ends. It also seems very easy to clean the crevices are very short and you are able to wipe things out with ease.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 10, 2026
★★★★★ 5
Really comfortable upgrade from my old desk chair
Color: Beige
My old desk chair had been getting pretty uncomfortable, so I decided to replace it with this white one. After using it for a few days, I can definitely say it’s been a really nice upgrade for my workspace.
My old chair was starting to feel stiff and uncomfortable after sitting for a while. This one is a lot wider and softer, which I really appreciate. Sometimes I sit cross-legged when I’m working on my laptop, and this chair actually has enough space to do that comfortably.
The flip-up arms are also really practical. When I’m not using them, I just flip them up and push the chair under my desk. My workspace feels a lot less cramped now.
The wheels roll smoothly and the height adjustment was easy to set up. I also didn’t expect to use the side pockets much, but I’ve been keeping a notebook and my tablet there, which is actually pretty convenient.
I mainly bought the white color because I wanted something simple for my home office, and it looks really clean in the room.
After switching from my old chair, working at my desk has been a lot more comfortable. It’s been great for longer work sessions, and overall I’m really happy I decided to get this one.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 16, 2026
recommand products
Sports Series 4.5" High Flow Catted Downpipe for the B58 (6 Cylinder) Engine
472.50
Sports Series 4" High Flow Catted Downpipe for the 2020-24 M135iX B48 (4 Cylinder) Engine
472.50
Competition Series Mid Pipes 2023+ M2 S58 Engine
597.50
Competition Series Catless Primary Downpipe 2023+ XM S68 Engine
497.50
Competition Series Front Mount Intercooler for 2007-10 535i Engine Basic Kit
547.50