Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 10 - Jul 15
For Your Every Summer RSVP, with Code: SUMMER15
Description
Bosch GVT600-13 Contact Voltage Tester Auto Ranging AC DC Volt Meter GFCI Circuit Detector CAT IV 600V Electrician Diagnostic ToolSimplify Circuit Diagnostics with the Bosch GVT600 13 Auto Ranging Voltage Tester The Bosch GVT600 13 Professional Contact Voltage Tester is the ultimate handheld diagnostic solution designed to provide fast, reliable electrical testing for electricians, HVAC techs, and facility maintenance crews. Equipped with an intuitive auto ranging processor, this heavy duty pocket digital meter instantly detects and measures both AC and DC voltages up to 600V
Simplify Circuit Diagnostics with the Bosch GVT600-13 Auto-Ranging Voltage Tester
The Bosch GVT600-13 Professional Contact Voltage Tester is the ultimate handheld diagnostic solution designed to provide fast, reliable electrical testing for electricians, HVAC techs, and facility maintenance crews. Equipped with an intuitive auto-ranging processor, this heavy-duty pocket digital meter instantly detects and measures both AC and DC voltages up to 600V without the hassle of manual dial selections. Its integrated GFCI compatibility makes it an ideal instrument for safely testing residential outlets, commercial switches, branch circuits, and main breaker panels with total accuracy and absolute confidence.
Engineered to survive the most demanding industrial jobsites, the GVT600-13 features a rugged, rubber-reinforced overmolded housing boasting an IP54 weather rating for enhanced dust and water resistance. It is strictly built to certified CAT IV 600V safety standards, providing premium user protection when troubleshooting high-voltage electrical installations. Complete with a high-contrast inverted screen for crisp readability, a high-output LED panel flashlight for unlit utility closets, and fully replaceable professional test leads, this compact safety tool delivers the ultimate blend of portability and structural durability.
Key Features
- Intelligent Auto-Ranging Testing: Automatically identifies and measures AC/DC voltages up to 600V, eliminating manual scale adjustments for seamless field operations.
- GFCI Receptacle Compatibility: Specialized internal circuitry enables quick verification of ground fault circuit interrupter outlets and breaker systems.
- Certified CAT IV 600V Safety: Rigorously tested and certified to elite electrical safety standards for secure usage inside dense commercial load panels.
- Rugged Rubber-Enforced Shell: Impact-resistant over-molded housing safeguards sensitive internal electronics from drops and jobsite abuse.
- High-Contrast Inverted Screen: Delivers sharp, clear measurement readability in blinding outdoor sunlight or pitch-black residential crawlspaces.
- Integrated Panel Flashlight: High-efficiency built-in LED torch illuminates dark wire bundles, junction boxes, and enclosed breaker cabinets.
- Fully Replaceable Test Leads: Includes detachable premium silicone test leads to ensure maximum field service flexibility and tool longevity.
- IP54 Environmental Protection: Sealed structural construction provides ruggedized defense against fine airborne dust and splashing water.
What's Included
- (1) GVT600-13 Contact Voltage Tester
- (1) Set of TL90 Premium Test Leads
- (2) Standard AAA Batteries
Specifications
| Specification Parameter | Value / Range |
|---|---|
| Voltage Measurement Range | Up to 600V AC / DC |
| Ranging Type | Automatic Ranging |
| Safety Class Rating | CAT IV 600 V |
| Environmental Protection | IP54 Dust & Splash Resistant |
| GFCI Testing Compatibility | Yes |
| Display Type | High-Contrast Digital Screen |
| Integrated Flashlight | Yes (High-Output LED) |
| Product Length | 6.4 in. |
| Product Width | 2.6 in. |
| Product Height | 1.8 in. |
| Tool Weight | 0.47 lbs. |
| Power Supply | 2 AAA Alkaline Batteries |
| Operating Temperature Range | 14° F to 122° F |
| Test Lead Style | TL90 Removable / Replaceable |
Pro-Tip: When diagnostic testing a suspected dead branch circuit, always use the 'Live-Dead-Live' safety method with your GVT600-13. Check a known energized voltage source first to verify your tester displays power correctly, test the target deactivated circuit, and then re-verify back on the live source. This guarantees your tool is operating perfectly and prevents accidental exposure to unsafe live conductors due to hidden dead tester batteries!
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy