Description
35+7.5 uF MFD 370/440 VAC Dual Run Capacitor CBB65B - Fits AC Motor, Fan Start, Heat Pump - Replaces TRCFD3575, Z97F983035+7. 5 uf MFD 5% 370 or 440 Volt AC CBB65B Dual Run Round Capacitor Key Features Capacitance Rating: 35 + 7. 5 Microfarad (MFD) Capacitance Tolerance: 5% Voltage Rating: 370VAC or 440VAC Frequency: 50 60Hz Operating Temperature: 40C to +70C Shape: Round Construction: Aluminum case with three terminals (Common, Fan, Hermetic Compressor) Function: Serves as a dual run capacitor, supporting a compressor motor and a fan motor simultaneously. Replaces
35+7.5 uf MFD ±5% 370 or 440 Volt AC CBB65B Dual Run Round Capacitor
Key Features
- Capacitance Rating: 35 + 7.5 Microfarad (MFD)
- Capacitance Tolerance: ±5%
- Voltage Rating: 370VAC or 440VAC
- Frequency: 50/60Hz
- Operating Temperature: -40°C to +70°C
- Shape: Round
- Construction: Aluminum case with three terminals (Common, Fan, Hermetic Compressor)
- Function: Serves as a dual run capacitor, supporting a compressor motor and a fan motor simultaneously.
Replaces / Cross-Reference Part Numbers
- Replaces any brand of round dual run capacitor with matching 35/7.5 MFD capacitance and a voltage rating of either 370V or 440V.
- Compatible replacement for CBB65 and CBB65B type capacitors.
- Ensure the physical dimensions (diameter and height) fit your equipment's mounting bracket. A 440V capacitor can replace a 370V capacitor, but not vice-versa.
Compatibility & Fitment
- Designed for use in residential and commercial HVAC systems, central air conditioners, and heat pumps.
- Powers compressor and fan motors in outdoor condenser units.
- Suitable for various AC motor run applications that require a dual capacitor.
When to Replace
- The fan motor runs, but the compressor does not start.
- The air conditioner or heat pump makes a humming noise but will not start.
- The fan blades need a manual push to begin spinning.
- Visible signs of failure on the existing capacitor, such as a bulging top, swelling, or fluid leakage.
Installation Tips
- Warning: Disconnect all electrical power to the unit before performing service. Stored energy in a capacitor can cause severe electrical shock.
- Safely discharge the old capacitor by shorting across the terminals with an insulated screwdriver.
- Note or photograph the wire connections to the C (Common), FAN, and HERM terminals before disconnecting.
- Connect the wires to the corresponding terminals on the new capacitor.
- Secure the new capacitor with the original mounting strap.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy