SKU: 58501539091

Rat Na-K-ATPase ELISA Kit

Sale price$165.71 Regular price$184.12
Save 10%

Pay in installments of $46.03 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 14 - Aug 19

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Rat Na-K-ATPase ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: 1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20

Product Specification

Usage Experimental equipment required for the experiment:
1. Microplate reader (450nm)
2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL
3. 37℃ constant temperature box
4. Distilled water or deionized water

Sample processing and requirements:
1. Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing.
2. Plasma: Collect specimens using EDTA or heparin as an anticoagulant and centrifuge at 1000×g for 15 minutes at 2-8°C within 30 minutes of collection. Remove the supernatant for testing, or store at -20°C or -80°C, but avoid repeated freezing and thawing.
3. Cell culture supernatant: Centrifuge at 1000×g for 20 minutes. Remove the supernatant for testing, or store at -20°C or -80°C, but avoid repeated freezing and thawing.

Pre-Test Preparation:
1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature.
2. Prepare a gradient standard working solution: Add 1 mL of universal diluent to the lyophilized standard. Let stand for 15 minutes to completely dissolve, then gently mix (concentration 10 ng/mL). Then dilute to the following concentrations: 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, 0.15625 ng/mL, and 0 ng/mL. Serial dilution method: Take seven EP tubes and add 500 μL of universal diluent to each tube. Pipette 500 μL of the 10 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 5 ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details.
3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately.
4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately.
5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing).

Procedure:
1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C.
2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.)
3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes.
4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used).
5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes.
6. Washing: Discard the liquid and wash the plate five times as in step 4.
7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes.
8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm.

Calculating experimental results:
1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis.
2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor.

Theory This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a Na-K-ATPase (Na-K-ATPase) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue by HRP peroxidase and to yellow by acid. The intensity of the color is positively correlated with the amount of Na-K-ATPase (Na-K-ATPase) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Rat
Synonym Rat Na-K-ATPase ELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T  match   set remark
Pre-coating 96 Well plate 8 Hole ×12 Strip without
Standard 2 branch
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )  
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4 Zhang
without
Instructions
1 Share
without
Background Na-K-ATPase (Na-K-ATPase) is an enzyme present in the cell membranes of all animal cells (an electrically charged transmembrane ATPase). It plays several roles in cellular physiology. The Na⁺/K⁺-ATPase enzyme is active (i.e., it uses energy from ATP). For every ATP molecule used by the pump, three sodium ions are exported and two potassium ions are imported, resulting in a net output of positive charge per pump cycle. This enzyme belongs to the P-type ATPase family.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 0.156-10 ng/mL
Applications Serum, plasma, cell culture supernatant
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 58501539091

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.7 ★★★★★
Based on 13 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
B
Verified Purchase
BB #45
Whiting, US
★★★★★ 5
Best collar for hunting.
Style: Alpha TT 25
My dog uses this everyday. Nothing beats this collar for location, and training. This is the best collar for hunting.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 9, 2026
R
Verified Purchase
Rebecca Nipper
Boise, US
★★★★★ 5
Very pleased
Style: Alpha TT 25
My husband uses his garmin collar all the time. Works great and holds charge for several hours. He is very pleased with tracking distance.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on August 27, 2025
S
Verified Purchase
Stephen H.
West Palm Beach, US
★★★★★ 5
Links up easily
Style: Alpha TT 25
Love it and love the new charger connection
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 18, 2026
M
Verified Purchase
Mitch
San Leandro, US
★★★★★ 5
Adaptable to any dog
Style: Alpha TT 25
Fully scaleable from antenna to GPS unit. Holds charge well and durable. Could be cheaper.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 16, 2025
T
Verified Purchase
toadskipper
New York, US
★★★★★ 1
Garmin has been a super disappointment.
Style: Alpha TT 25
FOR THE REMOTE: For reasons I cannot fathom as a software developer, the Garmin developers chose to program the handheld to wait for GPS lock before allowing you to control the collar. This is stupid beyond belief and causes frustration that simply shouldn't be. Look Garmin, the remote should be able to communicate with the collar first and foremost. I want to be able to power everything up, put the collar on the dog, and walk out the door. If my dog sees a rabbit or deer, I want to be able to remind him not to chase. I DON'T want to stand there staring at my remote greeted by the message "Waiting for GPS" with all the buttons non-responsive. Fix this! This should be super easy to fix with a firmware update. Fix it and I'll gladly give this unit 10 stars! GPS is way too finicky to have to wait for it before using the basic controls. Update: SERIOUSLY!! HOT GARBAGE. This remote couldn't find a satellite if I stuck one up its... AGH.. and you can't communicate with your dog's collar until it does. FOR THE COLLAR: You won't be happy with the beeper.. It's super quiet. The light is an awesome feature. Vibration may work for your dog, mine doesn't seem to notice it at all. If the antenna was any longer it would pick up signals from outer space. Buy the shorter one if you decide to go with this unit and don't need to keep your dog from crossing an ocean. Seriously though... I'll never buy anything Garmin again. I would recommend you don't either.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 19, 2026

recommand products