SKU: 68829469346

Mouse SP ELISA Kit

Sale price$178.57 Regular price$198.41
Save 10%

Pay in installments of $49.60 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 14 - Aug 19

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Mouse SP ELISA KitProduct Specification Usage I. Sample Processing and Requirements 1. Serum: Place whole blood specimens collected in serum separator tubes at room temperature for 2 hours or at 4C overnight, then centrifuge at 1000g for 20 minutes. Remove the supernatant and store at 20C or 80C. Avoid repeated freezing and thawing. 2. Plasma: Collect specimens using EDTA or heparin as an anticoagulant. Within 30 minutes of collection, centrifuge at 1000g for 15

Product Specification

Usage

I. Sample Processing and Requirements


1.
Serum: Place whole blood specimens collected in serum separator tubes at room temperature for 2 hours or at 4°C overnight, then centrifuge at 1000×g for 20 minutes. Remove the supernatant and store at -20°C or -80°C. Avoid repeated freezing and thawing.


2.
Plasma: Collect specimens using EDTA or heparin as an anticoagulant. Within 30 minutes of collection, centrifuge at 1000×g for 15 minutes at 2-8°C. Remove the supernatant and test. Alternatively, store at -20°C or -80°C. Avoid repeated freezing and thawing.


3.
Tissue Homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove any residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh the tissue and mince it. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1g of tissue sample to 9mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly freeze-thawed. Finally, centrifuge the homogenate at 5000×g for 5-10 minutes. Remove the supernatant for analysis.


4.
Cell culture supernatant or other biological specimens: Centrifuge at 1000×g for 20 minutes. Remove the supernatant for testing, or store at -20°C or -80°C, but avoid repeated freezing and thawing.


Note: Hemolysis of the specimen will affect the final test results, so hemolyzed specimens are not suitable for this test.


II. Reagent Preparation


After removing the kit from the refrigerator, allow it to equilibrate to room temperature before use.


Dilution of 20× Wash Buffer: Dilute 1:20 with distilled water, i.e., add 1 part 20× Wash Buffer to 19 parts distilled water.


III. Procedure


1.
Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 20 minutes. Seal the remaining strips in a ziplock bag and return them to 4°C.


2.
Set up standard wells and sample wells. Add 50 μL of standard solution of varying concentrations to each standard well.


3.
Add 50 μL of the sample to be tested to the sample wells; leave blank wells untouched.


4.
Add 100 μL of horseradish peroxidase (HRP)-labeled detection antibody to each standard and sample well, except for the blank well. Seal the wells with sealing film and incubate at 37°C in a waterbath or incubator for 60 minutes.


5.
Discard the liquid, pat dry on absorbent paper, and fill each well with wash buffer (350 μL). Let stand for 1 minute, then discard the wash buffer and pat dry on absorbent paper. Repeat this process five times (a plate washer can also be used).


6.
Add 50 μL each of substrates A and B to each well and incubate at 37°C in the dark for 15 minutes.


7.
Add 50 μL of stop solution to each well. Within 15 minutes, measure the OD value of each well at a wavelength of 450 nm.


IV. Calculation of Experimental Results


Using the OD value of the measured standard as the horizontal axis and the concentration of the standard as the vertical axis, draw a standard curve on graph paper or using relevant software. Obtain a linear regression equation. Substitute the OD value of the sample into the equation to calculate the sample concentration.



Note: For reference only

Sensitivity The minimum detectable concentration was less than 1.0 pg/mL.
Species Reactivity Mouse
Theory The kit uses a double-antibody one-step sandwich enzyme-linked immunosorbent assay (ELISA). Samples, standards, and HRP-labeled detection antibodies are added sequentially to microwells pre-coated with mouse substance P (SP) capture antibodies. The assay is incubated and thoroughly washed. The color is developed using the substrate TMB, which converts to blue under peroxidase catalysis and to yellow under the action of acid. The intensity of the color is positively correlated with the amount of mouse substance P (SP) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Synonym Mouse Substance P (SP) ELISA Kit
Detection Type Used for in vitro quantitative detection of the content of mouse substance P (SP) in serum, plasma, tissue homogenate and related liquid samples.
Composition

Name

96 T

Remarks

Microwell enzyme plate

12 wells×8 strips

None

Standard product

0.3mL*6 tubes

None

Sample diluent

6mL

None

Detection antibody-HRP

10mL

None

20× wash buffer

25mL

Dilution according to the instructions

Substrate A

6mL

None

Substrate B

6mL

None

Stop solution

6mL

None

Seal film

2 sheets

None

Remarks:

1. The concentrations of the standard solutions are: 400, 200, 100, 50, 25, and 12.5 pg/mL.

2. After testing a large number of normal specimens, the normal concentration values of the specimens are all within the detection range provided by the kit. During the experiment, 50 μL of sample can be directly sampled. If some sample values exceed the maximum standard concentration, the sample can be appropriately diluted with sample diluent before the experiment.

General Notes

1. Strictly follow the specified incubation time and temperature to ensure accurate results. All reagents must reach room temperature (20-25°C) before use. Refrigerate reagents immediately after use.

2. Improper plate washing can lead to inaccurate results. Ensure that the liquid in the wells is as dry as possible before adding substrate. Do not allow the microwells to dry out during incubation.

3. Remove any residual liquid and fingerprints from the bottom of the plate, otherwise it will affect the OD value.

4. The substrate developer solution should be colorless or very light in color. Substrate solution that has turned blue should not be used.

5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.

6. Avoid direct exposure to strong light during storage and incubation.

7. Allow the sealed bag to equilibrate to room temperature before opening to prevent water droplets from condensing on the cold plate strips.

8. No reaction reagents should come into contact with bleaching solvents or the strong fumes emitted by bleaching solvents.

Any bleaching component will destroy the biological activity of the reagents in the kit.

9. Do not use expired products.

10. If there is a possibility of disease transmission, all samples should be managed properly and the samples and detection devices should be handled according to the prescribed procedures.

Storage Temp. Unopened test kit, stored at 2-8°C, has a shelf life of 6 months.
Test Range 12.5 pg/mL – 400 pg/mL.
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 68829469346

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.7 ★★★★★
Based on 10 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
L
Verified Purchase
LucyF
Cuba, US
★★★★★ 4
Feedback
Color: White, Size: without USB
I wish you didn’t have to adjust screws to adjust position Otherwise it is great
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 5, 2025
J
Verified Purchase
Jefferson T
Waukegan, US
★★★★★ 5
Easy to use
Color: Black, Size: without USB
Easy to use and set up. The quality of the item seems to be there - sturdy enough to hold my 34” ultra wide Samsung monitor. Worth every cent with how easy it is to use and readjust the angle of the screen - I had to stiffen the resistance to account for the added weight of the monitor, but the fit and stability is spot on once the adjustment was made; just a few turns of the screw with the included Allen key
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on October 26, 2025
A
Verified Purchase
Amazon Customer
Battle Creek, US
★★★★★ 5
Great quality and price
Color: Black, Size: without USB
The arm needed some additional tightening, but it’s holding my 32 in monitor perfectly. Great stability and mobility. The cable organizer is a bit awkward, but works well enough. I’ll probably stick with this brand in the future; the cost vs quality is amazing.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on October 31, 2025
T
Verified Purchase
Tinman
Louisville, US
★★★★★ 5
Great stand for the price!
Size: Quad, Style: Glass Free Stand, Size: Quad, Style: Glass Free Stand
It is a great stand. I was able to put everything together myself. Just wanted to point out a couple of things here. I have 2, 27" flat montors and 2, 37" curved monitors. Now the description says it will go up to 27", but I was able to get the 37" ones on this stand also. You can put them side by side - they will fit, but make sure you don't go over the weight limit, so for mine, to be sure I didn't exceed the weight limit, I have the bottom of them sitting on the and foot of the frame itself. You will not be able to angle them inwards toward yourself if you have 37" curved monitors. This is what I was hoping to do I just needed an extra inch on each side to move them out, for now I will just leave them side by side. For assembly, because I was doing this by myself, I found it easiest to leave all the moveable parts loose and lay the monitors out on the floor face down in the position I wanted them in (NO CABLES). Then I took the mostly assembled frame and adjusted it to my monitors. I put the plates on the monitors and then slid the appropriate piece of the frame onto each plate, still leaving most parts slightly loose (giving myself just enough play to move things around when I stood it up). I then stood the frame up and firmed down all the fittings once I got everything where I wanted it. I then lifted the entire stand with monitors up onto my desk and then began plugging in all the cables and cords. I really like the stand and it is a great value for the price. It is very sturdy with my setup. I just wish it had about an extra inch on at least the bottom two arms, but overall, definitely a great stand. (sorry for the bad photo but these are my work monitors and I could not show what was on the screens)
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 26, 2026
H
Verified Purchase
Hope Lyon
Boise, US
★★★★★ 5
Perfect! Level monitors, small footprint!
Size: Dual, Style: Glass Free Stand, Size: Dual, Style: Glass Free Stand
Perfect! This was the 3rd monitor stand I purchased this month. The others either were too bulky of a base and/or I could never get the monitors level! This is perfect! Was easy to assemble and it’s easy to move them & adjust tilt & spacing.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 24, 2026

recommand products