SKU: 97534322159

UA-Glo® BRET Ligand 618

Sale price$108.00 Regular price$120.00
Save 10%

Pay in installments of $30.00 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 17 - Aug 22

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

UA-Glo® BRET Ligand 618Product Specification Stability & Storage Dry ice transportation. Store away from light at 20C or below, and it is recommended to store for long term (>3 months) at 80C with a shelf life of 12 months. Background UA Glo BRET Ligand 618 is a red emitting fluorescent dye after excitation, which can serve as an energy acceptor in BRET (Bioluminescence Resonance Energy Transfer) experiments, particularly suitable for detecting protein protein interactions

Product Specification


Stability & Storage

Dry ice transportation. Store away from light at -20°C or below, and it is recommended to store for long-term (>3 months) at -80°C with a shelf life of 12 months.

Background

UA-Glo® BRET Ligand 618 is a red-emitting fluorescent dye after excitation, which can serve as an energy acceptor in BRET (Bioluminescence Resonance Energy Transfer) experiments, particularly suitable for detecting protein-protein interactions in live cells in NanoBRET™ assays. UA-Glo® BRET Ligand 618 can enter live cells and covalently bind to Halo-Tag® fusion protein A via its halogen group and the Halo-Tag®. When the BRET Ligand 618-labeled Halo-Tag® fusion protein A interacts with NanoLuc® fusion protein B, and in the presence of a NanoLuc® substrate such as UA-Glo® BRET Micro Luciferase Substrate, the luminescence produced by the reaction between NanoLuc® fusion protein B and the substrate can be absorbed by the nearby BRET Ligand 618. The red light emitted by the excited BRET Ligand 618 can be quantitatively detected and is directly proportional to the extent/amount of protein A and B interaction. Simultaneously measuring the NanoLuc® luminescence and calculating the ratio of BRET Ligand 618 to NanoLuc® luminescence can eliminate experimental errors and background interference, significantly enhancing detection sensitivity.

Components

UA-Glo® BRET Ligand 618 specifications are as follows:

BRET Ligand 618

Assays per 96-well plate

Assays per 384-well plate

20μL

200

500


Protocol

NanoBRETTM detection requires simultaneous measurement of the luminescence intensity of both the energy donor NanoLuc® and the energy acceptor BRET Ligand 618. The emission peak of NanoLuc® is at 460nm, while that of BRET Ligand 618 is at 618nm. For detecting donor luminescence, a BP filter around 460nm is recommended, such as Em 450nm/BP80. For detecting acceptor luminescence, an LP filter around 600-610nm is recommended, such as Em 610nm/LP. Suitable equipment includes multi-mode plate readers capable of BRET detection, such as the PerkinElmer EnVision®, BMG Labtech CLARIOstar®, and Promega GloMaxR Discover System. Filter selection and NanoBRETTM detection parameters can be referenced from the equipment manuals and related literature.

The following experiment demonstrates the application of UA-Glo® BRET Ligand 618 in NanoBRET® assays, using the interaction between Halo-Tag® fusion protein A and NanoLuc® fusion protein B as an example.

1)Co-transfect Halo-Tag® fusion protein A and NanoLuc® fusion protein B into HEK293 cells using transient transfection.

2)After approximately 20 hours of transfection, harvest the cells and resuspend them in phenol red-free Opti-MEM® I medium supplemented with 4% FBS at an appropriate density and volume.

3)UA-Glo® BRET Ligand 618 is provided as a DMSO solution at 1000x (0.1mM). Add it to the cells prepared in step 2) at a final concentration of 1x (0.1μM) and mix thoroughly. Include a control without BRET Ligand 618, adding DMSO to a final concentration of 0.1%.

4)Seed the cells prepared in step 3) into a clear-bottom white cell plate at an appropriate density: 96-well plate (90μL per well) or 384-well plate (36μL per well).

5)Dilute the test compounds in phenol red-free Opti-MEM® I medium with 4% FBS to 10x the final test concentration. Add to the cell plate prepared in step 4): 10μL per well for 96-well plates (final volume 100μL) or 4μL per well for 384-well plates (final volume 40μL). Ensure the final DMSO concentration does not exceed 0.5%.

6)Incubate the cell plate at 37°C, 5% CO2 for at least 4-6 hours or overnight (18-24 hours). Overnight incubation is recommended.

7)Prepare the NanoLuc® substrate: Dilute the UA-Glo® BRET micro-luciferase substrate (Youbio, L9002) 100-fold in phenol red-free Opti-MEM® I medium.

8)Remove the cell plate and add the substrate prepared in step 7): 25μL per well for 96-well plates or 10μL per well for 384-well plates. Mix by gently shaking the plate for 30 seconds.

9)Within 10 minutes of adding the substrate, measure the donor (460nm) and acceptor (618nm) luminescence signals using a multi-mode plate reader capable of NanoBRETTM detection.

10)Data processing: The ratio of acceptor (618nm) to donor (460nm) signals (BU, multiplied by 1000 to give mBU) represents the NanoBRETTM ratio. Calculate the NanoBRETTM ratio for both samples and the no-Ligand 618 control. The corrected NanoBRETTM ratio is obtained by subtracting the NanoBRETTM ratio of the no-Ligand 618 control from that of the sample.

Guidelines

1) Different batches are not recommended for mixed use 2) Without strict validation, it is not recommended to alter the dosage of detection reagents 3) For research use only 4) HaloTag, Nano-Glo, and NanoLuc are registered trademarks of Promega Corporation. NanoBRET is a trademark of Promega Corporation
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 97534322159

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.7 ★★★★★
Based on 28 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
K
Verified Purchase
Kourtney Reopelle
Lowell, US
★★★★★ 5
Size matters
Have a nice container that can holds a lot but not so tall and skinny like most to the point that their top heavy and tip over. I feel like this one has the balance between being large without taking a too much space and also holding a lot
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 25, 2026
S
Verified Purchase
Steve Odom
Grantham, US
★★★★★ 5
Large capacity, Sturdy construction
Size: 2 Gallon, Unit Count: 1.0
Very large capacity. Strong plastic construction. I use an auto injector once a week. This container will probably last me a year, yet it will easily fit in the sharps. Disposal receptacle in town.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 23, 2026
R
Verified Purchase
Rena J.
Birmingham, US
★★★★★ 5
This container is perfect
A durable container that will hold a good amount of syringes. Great for home usage.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 20, 2026
J
Verified Purchase
James Dieter
Lexington, US
★★★★★ 5
Nice size for storage.
Size: 5 Quart, Unit Count: 2.0
Nice size for my Lantus pens. The price was very reasonable. Sturdy with a nice locking lid.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 24, 2026
D
Verified Purchase
Dawn E
Waukegan, US
★★★★★ 5
Exactly as expected.
Size: 5 Quart, Unit Count: 1.0
Exactly what it is made for. It is a perfect size for months worth of needles that we are using for our peptide injections.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 20, 2026

recommand products