SKU: 27215970383

RNase Inhibitor ELISA Kit

Sale price$532.35 Regular price$591.50
Save 10%

Pay in installments of $147.88 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 17 - Aug 22

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

RNase Inhibitor ELISA KitProduct Specification Usage 1. Preparation: 1. Before using all components of reagent and sample under test needs to be restored at room temperature. 1 x for Wash Buffer preparation: 20 x will Wash Buffer balance to room temperature to crystallization completely dissolved, using deionized water or ultrapure water diluted 20 times after blending, diluted 1 x for Wash Buffer every hole are use 3 ml, in 2 8 can keep stable for 1 week. 2. RNase Inhibitor

Product Specification

Usage 1. Preparation:

1. Before using all components of reagent and sample under test needs to be restored at room temperature.

1 x for Wash Buffer preparation: 20 x will Wash Buffer balance to room temperature to crystallization completely dissolved, using deionized water or ultrapure water diluted 20 times after blending, diluted 1 x for Wash Buffer every hole are use 3 ml, in 2-8 ℃ can keep stable for 1 week.

2. RNase Inhibitor Detection Antibody Dilution: before using blender, and then use Dilution Buffer 2 will RNase Inhibitor DetectionAntibody according to 1: 100 dilution ratio of dilution.

3. Preparation of the substrate solution: Color Reagent A and Color Reagent B were mixed according to 1:1, and then mixed for immediate use. The dosage of each hole 100 mu L. Do not use if the mixed substrate solution turns blue.

4. RNase Inhibitor dilution of Standard: 6μL RNase Inhibitor Standard stock solution (10μg/mL) was diluted 100-fold with 594 μl dilution Buffer 1 as the first gradient (100ng/mL). Then take 100 ng/mL concentration sample 300 mu L to new EP tube, add 300 mu L Dilution Buffer1, double gradient Dilution, Dilution into 50, 25, 12.5, 6.25, 3.125 and 1.5625 ng/mL, a total of seven levels.


In order to ensure the validity of the experimental results, please use the newly prepared standard solution for each experiment.

2, the operation process:

1. All operating at room temperature, it is recommended that the standard and the sample under test to determine double complex hole.

1. sample incubation: will be diluted RNase Inhibitor of Standard and sample under test in enzyme label plate, respectively, 100 mu L/hole, blending, cover the seal plate membrane, 37 ℃ for 2 h incubation.

2. washing board: abandon to liquid in the hole, in 1 x for Wash Wash Buffer board, 300 mu L/hole, soak 30 s, washing board 5 times, the last time to pat dry residual liquid.

3. Inhibitor Detection Antibody incubation: after will dilute the RNase Inhibitor Detection Antibody in enzyme label plate, 100 mu L/hole, blending, cover the seal plate membrane, 37 ℃ for 1 h incubation.

4. Wash the plate: discard the liquid in the hole, wash the plate with 1×Wash Buffer, 300μL/ well, soak for 30s, wash the plate 5 times, and pat the residual liquid dry as much as possible for the last time.

5. Color development: The prepared substrate solution was added to the microplate, 100μL/ well, mixed, covered with plate sealing membrane, and incubated at 37 ° C in the dark for 20min.

6. Termination: Add Stop Reagent to the microplate, 50μL/ well, and gently shake the microplate until the color is uniform to ensure that the color development time of each well is the same.

7. reading value: enzyme label plate to be included in the enzyme standard instrument, read in 450 nm wavelength absorbance, read values within 20 minutes.

3. Data processing

If the OD value of the sample to be tested exceeded the OD value of the highest point of the standard curve, the sample should be diluted and measured again.

With standard concentration as the abscissa, standard values for the vertical suction light drawing standard curve. ELISACalc.exe regression and fitting calculation software is recommended for four-parameter fitting to calculate the concentration of RNase Inhibitor in samples.
Theory The kit is a double-antibody sandwich ELISA method, which is precoated with RNase Inhibitor to capture antibody. After adding the sample, the sample is captured to form antibody-antigen complex, and then HRP-labeled RNase Inhibitor is added to detect antibody. An antibody-antigen-antibody "sandwich" complex was formed. Finally, TMB was added for color development, and the absorbance (OD) value was read at 450nm wavelength after the reaction was terminated. The RNase Inhibitor content in the sample was positively correlated with the OD value.
Description RNase Inhibitor can specifically inhibit the activities of RNase A, B and C, and can form a 1:1 complex with RNase, thereby inhibiting its activity.
        In the process of drug mRNA vaccine production, RNase Inhibitor can effectively inhibit the reaction system of possible RNase activity, so as to protect the mRNA degradation. According to the regulation, need to concentrate to the residue detection of mRNA vaccine, including RNase Inhibitor as protein product is belong to the category of protein residue test items, so we need the residues were quantitative detection.
        This kit, double antibody sandwich enzyme-linked immunoassay (ELISA) to detect RNase Inhibitor, with high sensitivity and specificity of detection and quantitative analysis of RNase Inhibitor content.

Product Features:
Sensitivity: 3.125 ng/ml
Detection Range: 3.125 100 ng/ml
Composition
Components Descriptions Size
RNase Inhibitor Microplate Package is capture antibody 96T/Kit
RNase Inhibitor Detection Antibody HRP was labeled and the dilution ratio was 1:100 150μl
RNase Inhibitor Standard Restructuring RNase inhibitor (5 mu g/ml) 150μl
20×Wash Buffer scrubbing solution 30ml×2
Sample Dilution Buffer Sample diluent 30ml
Conjugate Dilution Buffer enzyme diluent 15ml
Color Reagent A Color liquid A 6ml
Color Reagent B Color liquid B 6ml
Stop Reagent stop buffer 6ml
Sealing Film sealing film
General Notes 1, before the experiment should be in accordance with the requirements of relevant experimental reagent balance to room temperature.
2, each reagent should be fully mixed before use to ensure the uniformity and accuracy of the reagent.
3, strictly control the reaction temperature and reaction time.
4, measurements can not beyond the normal range.
5, the number of washing plate, the amount of washing plate liquid, the soaking time of washing plate liquid, and the strength of washing plate are the problems that should be paid attention to.
6, when the termination reaction to avoid microporous of bubbles.
7. The corresponding standard curve should be prepared for each test, and the standard curve of different kits and different days should not be mixed.
8, pay attention to the change in time between different samples and steps with tray and spear, avoid cross contamination.
9, reading the light absorption value should be completed within 20min after adding the termination solution.
10, color with high concentration may produce black floc, belongs to the normal phenomenon, lightly don't affect the reading result.
Storage Temp. Dry and keep away from light at 2-8 ° C, valid for 12 months.
Test Range 3.125-100 ng/ml
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 27215970383

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.5 ★★★★★
Based on 18 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
C
Verified Purchase
Chantell B.
Carnegie, US
★★★★★ 5
Fits perfect
Fits perfect in 2018 x5
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 10, 2026
R
Verified Purchase
RichD
West Palm Beach, US
★★★★★ 5
OEM quality
BMW dealer wanted $300 to replace the cabin filters. Watched a 5 minute video and ordered these up. Look identical to OEM and easiest cabin filters I've installed. Save yourself a ton of money and install these yourself. BMW quality without the BMW price.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on August 26, 2025
D
Verified Purchase
Dmytro Sushynskyi
Lake Worth, US
★★★★★ 5
Great filter!
Excellent filter! Fits my 2017 BMW X5 f15. Eliminates all external odors from the street.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 23, 2025
S
Verified Purchase
Shahida M Parveen
Natrona Heights, US
★★★★★ 4
Fits bmw x5 35i 2015
Installation was pretty easy. Works as designed. Will update.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on July 16, 2023
M
Verified Purchase
MLG
Pawtucket, US
★★★★★ 5
Great price
I love Mann filters. Great for the price and great quality. I was surprised how cheap they were ( my car takes 2 filters and two come in the box). They fit like a glove and now I am enjoying fresh air
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 30, 2026

recommand products